Hyundai Kona: Air Conditioning System / Ambient Temperature Sensor Description and operation

Description
The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.
The sensor output will be used for discharge temperature control, temperature regulation door control, blower motor level control, mix mode control and in-car humidity control.

  
If the ambient temperature is below 2.0°C (35.6°F), the A/C compressor will stop.
The compressor will operate manually.
Photo Sensor Repair procedures
Inspection 1. Turn the ignition switch ON. 2. Connect the GDS. 3. Emit intensive l ...

Ambient Temperature Sensor Repair procedures
Inspection 1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature. ...

Other information:

Hyundai Kona (OS) 2018-2024 Service Manual: Repair procedures
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the glove box. (Refer to Body - "Glove Box Upper Cover Assembly") 3. Remove the smart key unit. ...

Hyundai Kona (OS) 2018-2024 Service Manual: RCV Control Solenoid Valve Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the RCV connector. 3. Measure resistance between the RCV terminals 1 and 2. 4. Check that the resistance is within the spec ...