Description
RCV (Recirculation Valve) Control Solenoid Valve is installed on the cooling pan motor top and operates the RCV actuator which controls the by-pass passage of the turbo-charger compressor.
When the throttle valve is closed during engine running [Tip-out], crash noise of the impeller will occur because of rapid increasing of the boost pressure. So, in this case, in order to prevent this phenomenon, ECM maintains the appropriate boost pressure by opening the by-pass passage.

Electric WGT Control Actuator Schematic diagrams
Circuit Diagram ...

RCV Control Solenoid Valve Specifications
Specification Item Specification Coil Resistance (Ω) 28.3 - 31.1 [20°C (68°F)] ...

Other information:

Hyundai Kona (OS) 2018-2024 Service Manual: Fuel Pressure Control Valve (FPCV) Specifications
Specification Item Specification Coil Resistance (Ω) 0.5 [20°C (68°F) ...